ST-3205N Extractive Sampling System
The ST-3205N extraction-type sampling system (hereinafter referred to as the “system”) is a safety monitoring interlock device specially designed and manufactured for the operation and production of extraction-type explosion-proof process equipment. The complete system includes an analysis unit, an instrument calibration unit, and other components.
Keywords:
Category:
Process Analysis System
Hotline:
Friendly Reminder : Customizable based on actual needs—welcome to call for more information.
Product Overview
The ST-3205N Extractive Sampling System (hereinafter referred to as the “system”) is a safety monitoring interlock device specifically designed and manufactured for the operation and production of extractive, explosion-proof process equipment. The complete system comprises an analysis unit, an instrument calibration unit, and other components. Building upon the strengths of similar foreign products, this system has been specially designed to meet the current characteristics of furnace compositions and the features of dry- and wet-process purification equipment. This process analysis system has been successfully implemented in over 30 enterprises engaged in the production of furnace-process purification equipment, bringing these companies both significant economic and social benefits.
Product Principle
The gas detection transmitters in this system employ electrochemical sensors imported from overseas (for combustible gases, catalytic combustion sensors are used). They operate on the principle of controlled-potential electrolysis. Inside the electrolytic cell, three electrodes—working electrode, counter electrode, and reference electrode—are arranged and separated from the external environment by a thin membrane. A specific polarization voltage is applied across these electrodes. The gas to be measured diffuses through the membrane and reaches the working electrode, where an oxidation-reduction reaction occurs. As a result, the sensor outputs a corresponding current, which is directly proportional to the concentration of the gas being measured. This current signal is first converted into a voltage signal via diffusion-based sampling and amplification, and then passed through a voltage-to-current conversion circuit, transforming the varying voltage signal into a current signal for output.
Working conditions
Operating conditions:
1. Dust content of the sample gas: <200 g/Nm³;
2. Medium temperature: 20–800℃;
3. Medium pressure: > -10 kPa;
4. Moisture content: Suitable for saturated water vapor (sampling requires a heated pipeline);
Climate conditions:
1. Ambient temperature: -25~55℃;
2. Relative ambient humidity: 20–85%;
3. Atmospheric pressure: 70–106 kPa;
4. Sunlight exposure: No direct exposure;
5. Airflow velocity: Direct airflow < 3 m/s;
Environmental conditions:
1. The installation site has no obvious vibration and no strong electromagnetic interference.
2. Install a dedicated ground wire (with a grounding resistance of less than 2Ω).
3. No volatile, corrosive, or explosive gases;
4. Well-ventilated;
Performance metrics
1. Measurement range and resolution:
CO: 0–1000 ppm, 1 ppm / NH3: 0–100 ppm, 1 ppm / H2S: 0–200 ppm, 1 ppm / Methane: 0–100% LEL, 1%
2. Operating voltage: DC 12V~36V
3. Monitoring accuracy: ±3%
4. Response time: O2 ≤ 30s; CO ≤ 40s; combustible gas ≤ 20s;
5. Transmission distance: Less than 1000 m
6. Output signal: RS485 \ Dual-bus \ 433 MHz
7. System cabinet external dimensions: Depth × Width × Height = 600 × 500 × 1000 mm;
8. Explosion-proof, protection rating: IP65
9. Sensor Type: Electrochemical (for combustible gases, catalytic combustion type; other types are specified separately)
Product Features
1. Equipped with a first-class sampling and sample-preprocessing system in China, the entire system features long maintenance intervals, minimal maintenance requirements, simple and convenient operation, and high reliability.
2. Adopting an analytical cabinet-type (or analytical room-type) structure, we have completed a “turnkey engineering design,” simplifying installation and commissioning while enhancing system reliability.
3. Utilizing technologies such as dry-process flow, pulse cleaning, and electric heating mixing, it features automatic sample introduction, continuous operation, and interlock control functions.
4. It employs a high-performance diaphragm vacuum pump imported from abroad, featuring strong corrosion resistance, large pumping capacity, high temperature tolerance and reliability, long service life, and low maintenance requirements.
5. It is resistant to moisture, dust, and corrosion; minimally affected by ambient temperature fluctuations; immune to vibration impacts; operates with high stability; requires infrequent calibration; and boasts a service life of over five years.
6. Short system response time: The system responds rapidly. Each probe is equipped with a diaphragm sampling pump, ensuring a short response time. When the sampling line is less than 10 meters long, the response time is under 10 seconds.
7. Low operating costs, minimal maintenance requirements, and virtually zero long-term operational wear and tear.
Scope of application
1. Custom-made cabinet made of stainless steel, featuring a door-opening structure on both the front and rear sides;
2. This device is suitable for the automatic analysis and monitoring of the concentrations of EX, CO, O2, and other substances at various monitoring points in any explosion-proof process, thereby ensuring the operational safety of these processes.
Application areas
Petroleum & Petrochemical / Natural Gas / Iron and Steel Metallurgy / Air Separation / Cement and other industries
Other products
ST9700CN type of Cement Kiln Analysis System
Control the combustion of cement kilns, and analyze the gases concentrations of CO, O2, CO2, SO2 and other gases in the smoke chamber of kiln tail.
View detailsAir Separation Process Analysis System
In the petrochemical and metallurgical industries, air separation & purification equipment are widely used to separate O2, N2, Ar and other rare gases from the air, and take these gases as raw material gas as well as on-site protective gas.
View detailsST9800CN type of Exhaust Gas Purification Analysis System for closed Silicon-Manganese Furnace
The ST9800CN type of exhaust gas purification analysis system for closed silicon-manganese furnace (hereinafter referred to as the device) is a safely monitoring & interlocking device, which is specially designed and manufactured for operation & production of the closed silicon-manganese furnace process equipment.
View detailsST9800CN type of Positive Pressure Explosion-proof Analysis System
The ST9800CN type of positive pressure explosion-proof analysis system (hereinafter referred to as the device) is a safety monitoring interlock device, which is specially designed & manufactured for operation and production of positive pressure explosion-proof process equipment.
View detailsST9100CN type of Coke-Oven Coal Gas Analysis System
Coke-oven coal gas is an important by-product in the coke production process, it can be used as recycled energy in power plants and can be used as household coal gas as well, it is also able to be reused as raw material gas for synthetic natural gas/LNG.
View detailsST9500cn type of Explosion-proof Oxygen Analysis System for Natural Gas Process
The ST9500CN type of explosion-proof oxygen analysis system for natural gas process (hereinafter referred to as the device) is a safety monitoring & interlocking device, which is specially designed and manufactured for the operation & production of explosion-proof process equipment in accordance with specific processes.
View detailsRH2000CN type of Natural Gas Dew-Point Analysis System
LNG is the abbreviation for Liquefied Natural Gas, which is a product of natural gas that has been purified and cooled to a liquid state under ultra-low temperature conditions. The composition of LNG not only determines its usage characteristics but also holds significant importance for process design, accounting, and practical applications.
View detailsRHCK 590LEx type of Analysis System for Ammonia-Cracked Hydrogen Production
In order to realize real-time, continuous and accurate online monitoring of the hydrogen concentration in the cracking gases which are produced by the ammonia-cracked furnace; promptly provide feedback on the working conditions of cracking reaction; and guide the optimization of process parameters (furnace temperature, ammonia feed amount, system pressure) as well as eliminate problems such as hidden cracking-hazards and sub-standard hydrogen purity etc. Therefore this technical solution of online hydrogen analyzer is specially formulated, so as to provide data support for full-process automated control and operation of the ammonia-cracked furnace.
View detailsST9800CN type of Online Analysis System for Calcium Carbide Furnace Exhaust Gas
The ST9800CN type of online analysis system for calcium carbide furnace exhaust gas (hereinafter referred to as the device) is a safely monitoring & interlocking device, which is specially designed and manufactured for operation & production of calcium carbide furnace process equipment.
View detailsST9800CN type of process analysis system for closed calcium carbide furnace is modularly designed according to specific working condition parameters & requirements of calcium carbide furnace factory---as well as by means of adopting our company’s mature sampling pretreatment technology and analysis & control technology.
View detailsRHCK350LEx type of Oxygen Content Online Analysis System
The RHCK350LEx type of oxygen content online analysis system is used for analyzing oxygen content in gas pipelines. The online analysis system consists of a sampling system, a pretreatment system, a calibration system, an explosion-proof oxygen gas analyzer, a sub-cabinet, and its public utilities etc.
View detailsST9600CN type of Analysis System for Petrochemical Industry
This system provides enterprises with overall solutions that meet actual needs, targeting the common characteristics of the petrochemical industry, such as numerous devices, complex operating conditions, and high hazard levels.
View detailsONLINE MESSAGE
*Note: Please ensure that the information you provide is accurate and that your contact details remain up-to-date. We will get in touch with you as soon as possible.