It emits alarm signals to alert people to take appropriate measures, and can record information such as alarm events, fault events, and operation logs, making it convenient for users to query and trace these records. This facilitates the analysis and management of emergency situations and system operating conditions.
Keywords:
Category:
Combustible/Toxic and Hazardous Gas Bus Control System
Hotline:
Friendly Reminder : Customizable based on actual needs—welcome to call for more information.
Product Overview
It emits alarm signals to alert people to take appropriate measures and prevent hazards such as explosions and fires. It can record information on alarm events, fault events, operation logs, and other relevant data, making it easy for users to query and trace these records. This facilitates the analysis and management of emergency situations and system operating conditions.
Product Parameters
1. Host Capacity: The system can connect up to 250 bus-based digital detectors or 32 channels of 4-20mA analog detectors. Analog and digital channels cannot be used simultaneously.
2. LCD: Resolution 320*240, 5.1 inches
3. Processor: ARM7
4. Gas detected: O 2 EX, CO, H 2 S, CL 2 Wait
5. Display mode: You can choose to display 4 items per page or 14 items per page.
6. Inspection interval: 0.2s
7. Page change interval: 4–14 seconds (adjustable)
8. Single-channel display: Allows monitoring the gas concentration of only a single transmitter.
9. Online Settings: You can set the parameters, perform calibration, and adjust the zero point of the bus transmitter online.
10. Switch outputs: 1 common relay. If equipped with a relay control box, there are 32 configurable relays and 1 common relay. If equipped with an 8-channel relay control board, there are 8 configurable relays.
11. Real-name input: You can enter the installation address of the device, using Chinese characters, numbers, and letters.
12. Data Storage: Can store over 3,200 gas alarm and power-on records, using a circular overwrite storage method.
13. Communication interfaces: 2 RS232 ports, 2 RS485 ports.
14. Serial port 1 RS485 communicates with the bus transmitter.
15. Serial port 2 can be connected to a 32-channel relay control box (optional), linked to a computer for reading the controller’s alarm records and parameters, equipped with standard Modbus RTU output (optional), and standard Modbus TCP output (optional; requires an Ethernet-to-serial module).
16. Communication rate: 9600 bps (default)
17. Transmission Distance: The maximum distance between the detector and the controller is ≤ 1000 meters.
18. Installation method: Wall-mounted
19. System power supply: AC 220V ±15%, 50Hz ±1%
20. Transmitter power supply: DC 24V
21. Operating temperature: -10℃ to 50℃
22. Ambient humidity: ≤95% RH
Application areas
Power plants / Petrochemicals / Natural gas / Iron and steel metallurgy / Environmental wastewater treatment and other industries
Other products
ST9700CN type of Cement Kiln Analysis System
Control the combustion of cement kilns, and analyze the gases concentrations of CO, O2, CO2, SO2 and other gases in the smoke chamber of kiln tail.
View detailsAir Separation Process Analysis System
In the petrochemical and metallurgical industries, air separation & purification equipment are widely used to separate O2, N2, Ar and other rare gases from the air, and take these gases as raw material gas as well as on-site protective gas.
View detailsST9800CN type of Exhaust Gas Purification Analysis System for closed Silicon-Manganese Furnace
The ST9800CN type of exhaust gas purification analysis system for closed silicon-manganese furnace (hereinafter referred to as the device) is a safely monitoring & interlocking device, which is specially designed and manufactured for operation & production of the closed silicon-manganese furnace process equipment.
View detailsST9800CN type of Positive Pressure Explosion-proof Analysis System
The ST9800CN type of positive pressure explosion-proof analysis system (hereinafter referred to as the device) is a safety monitoring interlock device, which is specially designed & manufactured for operation and production of positive pressure explosion-proof process equipment.
View detailsST9100CN type of Coke-Oven Coal Gas Analysis System
Coke-oven coal gas is an important by-product in the coke production process, it can be used as recycled energy in power plants and can be used as household coal gas as well, it is also able to be reused as raw material gas for synthetic natural gas/LNG.
View detailsST9500cn type of Explosion-proof Oxygen Analysis System for Natural Gas Process
The ST9500CN type of explosion-proof oxygen analysis system for natural gas process (hereinafter referred to as the device) is a safety monitoring & interlocking device, which is specially designed and manufactured for the operation & production of explosion-proof process equipment in accordance with specific processes.
View detailsRH2000CN type of Natural Gas Dew-Point Analysis System
LNG is the abbreviation for Liquefied Natural Gas, which is a product of natural gas that has been purified and cooled to a liquid state under ultra-low temperature conditions. The composition of LNG not only determines its usage characteristics but also holds significant importance for process design, accounting, and practical applications.
View detailsRHCK 590LEx type of Analysis System for Ammonia-Cracked Hydrogen Production
In order to realize real-time, continuous and accurate online monitoring of the hydrogen concentration in the cracking gases which are produced by the ammonia-cracked furnace; promptly provide feedback on the working conditions of cracking reaction; and guide the optimization of process parameters (furnace temperature, ammonia feed amount, system pressure) as well as eliminate problems such as hidden cracking-hazards and sub-standard hydrogen purity etc. Therefore this technical solution of online hydrogen analyzer is specially formulated, so as to provide data support for full-process automated control and operation of the ammonia-cracked furnace.
View detailsST9800CN type of Online Analysis System for Calcium Carbide Furnace Exhaust Gas
The ST9800CN type of online analysis system for calcium carbide furnace exhaust gas (hereinafter referred to as the device) is a safely monitoring & interlocking device, which is specially designed and manufactured for operation & production of calcium carbide furnace process equipment.
View detailsST9800CN type of process analysis system for closed calcium carbide furnace is modularly designed according to specific working condition parameters & requirements of calcium carbide furnace factory---as well as by means of adopting our company’s mature sampling pretreatment technology and analysis & control technology.
View detailsRHCK350LEx type of Oxygen Content Online Analysis System
The RHCK350LEx type of oxygen content online analysis system is used for analyzing oxygen content in gas pipelines. The online analysis system consists of a sampling system, a pretreatment system, a calibration system, an explosion-proof oxygen gas analyzer, a sub-cabinet, and its public utilities etc.
View detailsST9600CN type of Analysis System for Petrochemical Industry
This system provides enterprises with overall solutions that meet actual needs, targeting the common characteristics of the petrochemical industry, such as numerous devices, complex operating conditions, and high hazard levels.
View detailsONLINE MESSAGE
*Note: Please ensure that the information you provide is accurate and that your contact details remain up-to-date. We will get in touch with you as soon as possible.